https://koha.ing.unlp.edu.ar/logo-sii.jpg
Imagen de cubierta local
Imagen de cubierta local
Imagen de Google Jackets

Design study of wind turbines 50kw to 3000kw for electric utility applications : volume I - Summary report / General Electric Company

Por: Colaborador(es): Tipo de material: TextoTextoIdioma: Inglés Series ERDA/NASADetalles de publicación: Cleveland : National Aeronautics and Space Administration, 1976; Washington : Energy Research and Development Administration 1976Descripción: pag. var. : figurasTema(s): Recursos en línea:
Contenidos:
Wind turbine configurations that would lead to generation of electrical power in a cost effective manner were considered. All possible overall system configurationss, operating modes, and sybsystem concepts were evaluated for both technical feasibility and compatibility with utility networks, as well as for economic attractiveness. A design optimization computer code was developed to determine the cost sensitivity of the various design features, and thus establish the configuration and design conditions that would minimize the generated energy costs. The preliminary designs of both a 500 kW unit and a 1500 kW unit operating in a 12 mph and 18 mph median wind speed respectively, were developed. The rationale employed and the key findings are summarized.
Tipo de ítem: Libro
Valoración
    Valoración media: 0.0 (0 votos)
Existencias
Biblioteca actual Signatura topográfica Estado Fecha de vencimiento Código de barras
Koha Ingenieria 621.548 GEN Bloque 14 (Navegar estantería(Abre debajo)) Disponible 44642

Informe/número de patente NASA CR-134934

ERDA/NASA/9403-76/1

GE-SD 76SDS4287

ERDA category UC-60

Wind turbine configurations that would lead to generation of electrical power in a cost effective manner were considered. All possible overall system configurationss, operating modes, and sybsystem concepts were evaluated for both technical feasibility and compatibility with utility networks, as well as for economic attractiveness. A design optimization computer code was developed to determine the cost sensitivity of the various design features, and thus establish the configuration and design conditions that would minimize the generated energy costs. The preliminary designs of both a 500 kW unit and a 1500 kW unit operating in a 12 mph and 18 mph median wind speed respectively, were developed. The rationale employed and the key findings are summarized.

No hay comentarios en este titulo.

para colocar un comentario.

Haga clic en una imagen para verla en el visor de imágenes

Imagen de cubierta local
BIBLIOTECA CENTRAL
    Calle 115 y 47 - (CP1900) La Plata
    Tel: (0221) 423-6689  int 118 -
    Email: bibcentral@ing.unlp.edu.ar
    Horario de atención: Lunes a Viernes de 8 a 19 hs..
    +54 2215900419

Con tecnología Koha